Old October 22nd 16, 07:22 PM posted to alt.collecting.juke-boxes
[email protected]
external usenet poster
 
Posts: 34
Default AMI F-120

Just bought this ami f-120. ac side is okay. seems as though I don't have any control power. took the junction box off after I checked the fuses. there is a black lead and a yellow lead hooked to the rectifier. When I put my black lead to the black wire and red lead from the meter to the yellow wire I get 76 volts. when I put the red wire on the 8/10 fuse holders it shows momemtarially 16 volts then immeditally goes to -1. same on both sides of holder. am I testing it right and if so does it mean my rectifier is bad. its still the same old rectifier it came out with. thanks for any help. norm
Ads
  #2  
Old October 23rd 16, 09:02 AM posted to alt.collecting.juke-boxes
[email protected]
external usenet poster
 
Posts: 7
Default AMI F-120

Norm, here is the schematic for the F. As you can see, the output from the transformer goes right to a bridge rect. The output should be approx 28 volts Dc

http://s1192.photobucket.com/user/Ro...l?sort=2&o=235

Check to be sure you are using the correct common point for ground return on your meter and correct scale. It looks like the low-Dc supply floats above chassis ( I may be missing the tie point) so measure across the rect out (DC) terminals.

It is a good idea to replace these old selenium units. A new silicon bridge will sag less and help speed up the old motors. I used typical 25amp 100volt (or more) bridge packages.

Rob-NYC

  #3  
Old November 21st 16, 07:36 PM posted to alt.collecting.juke-boxes
[email protected]
external usenet poster
 
Posts: 34
Default AMI F-120

On Saturday, October 22, 2016 at 1:22:04 PM UTC-5, wrote:
Just bought this ami f-120. ac side is okay. seems as though I don't have any control power. took the junction box off after I checked the fuses. there is a black lead and a yellow lead hooked to the rectifier. When I put my black lead to the black wire and red lead from the meter to the yellow wire I get 76 volts. when I put the red wire on the 8/10 fuse holders it shows momemtarially 16 volts then immeditally goes to -1. same on both sides of holder. am I testing it right and if so does it mean my rectifier is bad. its still the same old rectifier it came out with. thanks for any help. norm


thanks rob. I have a print for it. going to order a rectifier for it. just not sure where the wires goes. I think I know but not positive. thanks norm
 




Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts