View Single Post
  #3  
Old January 28th 17, 01:20 PM posted to alt.collecting.juke-boxes
Wayne B Wayne B is offline
Junior Member
 
First recorded activity by CollectingBanter: Aug 2010
Posts: 7
Default L-100 Scan twice, doesn't pick

Thanks John,

I'e cleaned the detent switch, but that did not help.

The troubleshooting manual is pointing towards a bad format, although I find that hard to believe.

I do have a replacement format arriving in a few days.

-Wayne
On Monday, January 23, 2017 at 2:32:27 PM UTC-5, John Robertson wrote:
On 2017/01/22 7:55 AM, Wayne B wrote:
Hi all,

I have a sick L-100.

Scans twice, doesn't pick. Battery test does not work. Tubes seem to be good, I have a new 2050 arriving this week, just in case.

The mech does trip if I pull the 12AX7, pull and replace the RCA plug or ground pins 3 or 5 of the 2050

TEU-1 was rebuilt a few years ago, all new caps and resistors.

I'm using a free play box.

Prior to this happening, if I'm correct (it was a while ago), intermittently, if I made a selection, the keys would not latch sometimes, and sometimes they would. Then it would pick. Then I heard a "pop" and since then, the keys latch, but the box does not pick anymore.

thoughts?


Detent switch dirty? Have you checked my Seeburg tips page for testing
processes?

http://flippers.com/Seeburg-trblshoot.html (handy if you have a 'scope
or even a voltmeter)

Theory he

http://flippers.com/Seeburg-tormat.html

John :-#)#

--
(Please post followups or tech inquiries to the USENET newsgroup)
John's Jukes Ltd. 2343 Main St., Vancouver, BC, Canada V5T 3C9
(604)872-5757 or Fax 872-2010 (Pinballs, Jukes, Video Games)
www.flippers.com
"Old pinballers never die, they just flip out."

Ads